01 / Industrial IoT · Sensing & Diagnostics

Before it breaks.
The machine tells you first.

A predictive maintenance sensor that mounts on equipment and catches early signs of failure through vibration and ultrasound.
We designed the sensor board circuit and layout and the RS-485 communication. The sensor is in use on equipment at Company S and Company L.

25 × 49 × 15mm
Sensor enclosure
3.2kHz
Vibration measurement (6kHz type available)
80kHz
Ultrasound bandwidth (combined type)
RS-485
Two-way link to the gateway

01 / Why Predictive

Failures don't come out of nowhere.
They send signals first.

Equipment problems show up in a sequence: ultrasound, vibration, noise and power, then heat. Ultrasound and vibration change months before a failure, noise and power weeks before, heat only days before. The earlier the stage you catch, the more room you have to plan maintenance and the lower the repair cost.

UltrasoundVibrationPowerNoiseHeatmonths beforemonths beforeweeks beforeweeks beforedays beforeFailureTime →
Concept diagram · Each dot marks the earliest point a problem can be detected. Actual timing depends on the equipment and the type of failure.

02 / Design Scope

One small enclosure.
Sensors and communication together.

We designed the sensor board circuit and layout, and the RS-485 communication with the gateway.

Predictive maintenance sensor in a black enclosure next to a Korean 100-won coin
Photo of the black sensor enclosure with mounting slots on both sides

The actual sensor · left, next to a 100-won coin for scale. Mounts with a magnet or bolts.

  1. 01

    Multi-sensor board circuit

    A 3-axis vibration sensor and a 2-axis inclinometer as standard, with optional ultrasound, temperature and other sensors depending on the type, all on one board.

  2. 02

    Compact layout

    Component placement and routing designed to fit a 25 × 49 × 15mm enclosure.

  3. 03

    RS-485 multi-drop

    Several sensors share one line, each identified by its own ID (A001, A002 …).

  4. 04

    Two-way communication

    The sensor sends its measurements when the gateway asks, and the gateway sends settings such as sampling rate, range and acquisition time down to the sensor.

  5. 05

    Industrial power input

    DC 24V / 12V input, operating temperature −40 to 80°C.

03 / System

Sensors on the floor.
Decisions at the gateway and server.

The sensors measure vibration and ultrasound on the equipment, and the gateway collects data from several sensors over RS-485 and passes it to the server.

IIoT serverStorage · analysisEdge gatewayCollection · processingSensor 1A001Sensor 2A002Sensor 3A003Sensor 4A004Sensor 5A005DataSettingsRS-485
Concept diagram · Five sensors are an example; the number on one line is set for each site.
  1. RequestThe gateway requests data from a sensor by its ID.
  2. SendThat sensor sends its measured and processed values over RS-485.
  3. UploadThe gateway uploads the collected data to the IIoT server.
  4. ConfigureThe server and gateway send new measurement settings down to the sensor.

Time domain

  1. Acceleration data (FIFO · high-pass filter)
  2. Velocity RMS (X · Y · Z)
  3. Acceleration peak (X · Y · Z)

Overall vibration level and momentary shocks, per axis.

Frequency domain

  1. Overlapping · windowing
  2. FFT
  3. Averaging
  4. Rescaling

How strong the vibration is at each frequency.

Calculated inside the sensor. Sampling rate, range and acquisition time are set at installation.

04 / Specifications

Small size.
Measurement you can configure.

Types

  • 3kHz typeVibration 3kHz
  • 6kHz typeVibration 6kHz
  • Combined 3kHzVibration 3kHz · ultrasound 80kHz
  • Combined 6kHzVibration 6kHz · ultrasound 80kHz

Standard specifications (3kHz type)

Vibration

Frequency
3.2kHz (resonance X · Y 3.0kHz, Z 2.2kHz)
Sampling rate
13 to 6,660Hz (10 steps)Set at install
Range
±2 · ±4 · ±8 · ±16gSet at install
Resolution
0.061 to 0.488 mg/LSB (by range)
Frequency resolution
128 to 1,024Set at install
Acquisition time
500 to 60,000msSet at install
Overlap
5 to 95%
Window
Rectangular · Hanning · Hamming · Flat Top

Inclinometer

Axes
X · Y
Range
±0.5 · ±1 · ±2 · ±3gSelectable
Temperature stability
Below 0.075mg/°C

General

Communication
RS-485 (two-way with the gateway)
Power
DC 24V / 12V
Operating temperature
−40 to 80°C
Size · mounting
25 × 49 × 15mm · magnet or bolts

Optional sensors · interfaces

Shock
±100 · ±200 · ±400g
Temperature
±0.5°C (−40 to 125°C)
Sound · ultrasound
100Hz to 80kHz
Humidity
±3.5%rH (20 to 80%rH)
Pressure
260 to 1,260hPa (absolute)
Tilt
0.076mg/digit
Wired interface
RS-485 or 10BASE-T1L (10Mbps · up to 1km)

05 / Field Data

Same machine.
Different waveforms.

A test on a linear stage: the sensor was attached and 3-axis vibration was compared between the normal state and three fault states. Each fault changes where the vibration rises and how it repeats.

  1. Normal3-axis vibration waveform in the normal state
  2. Broken retainer2 blocks3-axis vibration waveform with a broken retainer
  3. No grease4 blocks3-axis vibration waveform with no grease
  4. 4–5 balls removed2 blocks3-axis vibration waveform with four to five steel balls removed
Linear stage on the floor with sensor cables connected to each block

3-axis vibration · linear stage test. White, gray and dark gray are the three measurement axes.

Telling faults apart by ultrasound

Each fault shows up in a different frequency band with a different FFT pattern.

SymptomFrequency bandFFT patternTypical cause
Early bearing wear20 to 30kHzSteady, repeating high-frequency amplitude in a narrow bandFine ball-bearing damage, poor lubrication
Rotating friction25 to 40kHzContinuous high amplitude, fixed to a specific bandShaft friction, poor brush contact, wear
Bearing crack · rupture30 to 45kHzIrregular, high spike-shaped peaksOuter or inner race cracks, early breakage
Air · gas leak35 to 50kHzSustained high frequency across a wide band (looks like noise)Air, CO₂ or steam pressure leaks
Electrical spark · arc40 to 60kHz and aboveMomentary, random high-amplitude peaks across a wide bandSparks, discharge, electrical ripple, leakage current
  • 53kHzPower supply switching frequency
  • 40kHzUltrasonic sensor in operation
  • 27kHzArcing

Examples detected with the ultrasound sensor.

06 / Applications

For machines that can't stop.
Mounted first.

In use on equipment at Company S and Company L.

  • Vacuum pumps
  • Vacuum transfer robots
  • PCB process equipment
  • Display process equipment
  • Semiconductor process equipment
  • Logistics robots

From Sensor to System

Need a sensor for your equipment?
Start with what you want to measure.

We review the signal, the installation environment and the interface with you.

Discuss a similar project